Experimental ASD closure using autologous cell-seeded interventional closure devices
aDepartment of Paediatric Cardiology and Paediatric Intensive Care Medicine, Hannover Medical School, Carl Neuberg Strasse 1, D-30627 Hannover, Germany
bInstitute of Pathology, Hannover Veterinarian School, Hannover, Germany
* Corresponding author. Tel.: +49-511-5323-220; fax: +49-511-5329-038
Objective: Atrial septal defect (ASD) occluders are permanent implants in paediatric cardiology which serve as mechanical shields until complete overgrowth and incorporation of the occluding device by autologous tissue has occurred. Thereafter, the foreign body material making up the device is dispensable and bears potential long-term adverse effects. Rapid, firm and complete incorporation into the atrial septal wall should be a prerequisite for biodegradable devices. In this study, the feasibility of using autologous cell-seeded devices was investigated by (a) testing the influence of a collagen coating on cellular stress resistance in vitro and (b) comparing the short-term effects between cell-seeded, collagen-coated and acellular ASD occluders in vivo. Methods: Native and collagen-coated Dacon fabrics and Starflex-devices were pre-seeded with autologous fibroblasts (skin biopsy) and evaluated using various mechanical stress tests. In a sheep model interventionally created ASDs were closed using either autologous pre-seeded or conventional (acellular) Starflex-devices. Results: ASD closure devices were successfully pre-seeded with autologous cells. The incubation period needed, the cellular density achieved and the mechanical stability of the cytolayer after mechanical stressing (implantation) were improved by applying a collagen matrix on the fabric. Compared to the thin layer of ingrown tissue seen on conventional occluders after 30 days in vivo, a thicker layer of organising, newly formed granulation tissue on pre-seeded collagen-coated devices embedded not only the Dacron fabric, but also completely covered the spring arms of the device underneath a layer of neo-endothelium. Conclusion: Autologous cell pre-seeding of interventional closure devices is feasible since the cells survive the mechanical stress encountered during implantation. Rapid, firm and complete ingrowth of occluder devices into a thicker layer of young fibrous granulation tissue can be achieved, but an increased thrombogenicity currently limits the in vivo application.
KEYWORDS Atrial function; Cell culture/isolation; Congenital defects; Connective tissue; Histo(patho)logy
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
M. Sigler and C. Jux Biocompatibility of septal defect closure devices Heart, April 1, 2007; 93(4): 444 - 449. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Jux, H. Bertram, P. Wohlsein, M. Bruegmann, and T. Paul Interventional Atrial Septal Defect Closure Using a Totally Bioresorbable Occluder Matrix: Development and Preclinical Evaluation of the BioSTAR Device J. Am. Coll. Cardiol., July 4, 2006; 48(1): 161 - 169. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Pawelec-Wojtalik, J. Nozynski, M. Wojtalik, M. Piaszczynski, R. Surmacz, D. Bukowska, and W. Mrowczynski Is device closure for direct access valved stent implantation safe? Eur. J. Cardiothorac. Surg., July 1, 2006; 30(1): 4 - 9. [Abstract] [Full Text] [PDF] |
||||