© 1998 by European Society of Cardiology
Copyright © 1998, European Society of Cardiology
Mechanical modulation of stretch-induced premature ventricular beats: induction of a mechanoelectric adaptation period
Department of Physiology, Charing Cross and Westminster Medical School, St. Dunstans Road, Hammersmith, London W6 8RP, UK
* Corresponding author. Tel.: +44 (181) 8467643; fax: +44 (181) 8467338; e-mail: d.dick@cxwms.ac.uk
Objective: Mechanoelectric Feedback, a mechanical intervention inducing an electrical change, is gaining credence as a cause of cardiac arrhythmia in the clinical situation. However, the precise mechanism is unknown. To elucidate this we investigated mechanical and chemical modulation of stretch-induced premature ventricular beats. Methods: We positioned a balloon in the left ventricle of an isolated heart (New Zealand White rabbit), perfused by the Langendorff technique. Balloon inflation regularly produces premature ventricular beats. Monophasic action potentials, ECG's and pressure recordings monitored changes during mechanical intervention. The hearts were subjected to (i) variations in the degree of preload and duration of inflation, and (ii) cytoskeletal disrupters, colchicine and cytochalasin-B. Results: Mechanical dilation of the left ventricle can not only induce premature ventricular beats, but also induce a period during which premature beats cannot be re-induced on a subsequent inflation, i.e. a mechanoelectric adaptation period. The trigger for the mechanoelectric adaptation period seems to occur immediately on balloon inflation and required up to 60 s to recover. This period started with an undershoot in the diastolic component of the monophasic action potential as well as in the peak systolic pressure, with return to control levels within the period. Deflation produced an overshoot (rather than undershoot) in the monophasic action potential duration, but this also returned to control levels within the period. Changes in preload, duration of inflation and disruption of the cytoskeleton failed to modulate the mechanically induced premature beats, or the mechanoelectric adaptation period. Conclusions: Transient ventricular stretch produces arrhythmia, followed by an antiarrhythmic adaptive period. Possible mechanisms are related to a mechanical influence on stretch-activated channels, changes in ionic concentration or diffusion, or second messenger systems, which influence membrane potential. The arrhythmic adaptation does not appear to be related to the mechanical properties of the cytoskeleton. Final elucidation of the mechanism of the mechanoelectric adaptation period demonstrated, may prove important in determining the mechanism of stretch-induced premature ventricular beats and consequently arrhythmia management.
KEYWORDS Premature beats; Arrhythmia; Mechanoelectric feedback; Cytoskeleton; Stretch; Ventricle; New Zealand white rabbit
![]()
CiteULike
Connotea
Del.icio.us What's this?
This article has been cited by other articles:
![]() |
H. Huang, H. Wei, P. Liu, W. Wang, F. Sachs, and W. Niu A simple automated stimulator of mechanically induced arrhythmias in the isolated rat heart Exp Physiol, October 1, 2009; 94(10): 1054 - 1061. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Wang, R. W. Joyner, M. B. Wagner, J. Cheng, D. Lai, and B. H. Crawford Stretch-activated channel activation promotes early afterdepolarizations in rat ventricular myocytes under oxidative stress Am J Physiol Heart Circ Physiol, May 1, 2009; 296(5): H1227 - H1235. [Abstract] [Full Text] [PDF] |
||||
![]() |
C.-R. Kong, N. Bursac, and L. Tung Mechanoelectrical excitation by fluid jets in monolayers of cultured cardiac myocytes J Appl Physiol, June 1, 2005; 98(6): 2328 - 2336. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. Kiseleva, A. Kamkin, K.-D. Wagner, H. Theres, A. Ladhoff, H. Scholz, J. Gunther, and M. J. Lab Mechanoelectric feedback after left ventricular infarction in rats Cardiovasc Res, January 14, 2000; 45(2): 370 - 378. [Abstract] [Full Text] [PDF] |
||||



