Skip Navigation

Cardiovascular Research 2002 53(2):341-347; doi:10.1016/S0008-6363(01)00485-0
© 2002 by European Society of Cardiology
This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Wilkinson, I. B
Right arrow Articles by Webb, D. J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wilkinson, I. B
Right arrow Articles by Webb, D. J
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Copyright © 2001, European Society of Cardiology

High plasma concentrations of human urotensin II do not alter local or systemic hemodynamics in man

Ian B Wilkinsona,1, Jonathan T Affoltera, Sanne L de Haasa, M Paola Pellegrinia,2, Judith Boyda, Matthew J Winterb, Richard J Balmentb and David J Webba,*

aClinical Pharmacology Unit, Department of Medical Sciences, University of Edinburgh, Western General Hospital, Edinburgh EH4 2LH, UK
bSchool of Biological Science, G.38 Stopford Building, University of Manchester, Oxford Road, Manchester M13 9PT, UK

d.j.webb{at}ed.ac.uk

* Corresponding author. Tel.: +44-131-537-2006; fax: +44-131-537-2003

Received 17 July 2001; accepted 1 October 2001


    Abstract
 Top
 Abstract
 1. Introduction
 2. Methods
 3. Results
 4. Discussion
 References
 
Objective: Human urotensin II (hUII) is an endocrine hormone that acts as a potent arterial vasoconstrictor in both in vitro and in vivo studies in animals. We examined, for the first time, the local and systemic hemodynamic response to hUII in man in vivo. Methods: Four healthy male volunteers took part in pilot studies and 11 in definitive studies. Forearm blood flow (FBF) was measured in response to intra-arterial infusion of authentic, biologically active hUII (incremental rates of 0.001–300 pmol min–1) and saline placebo using venous occlusion plethysmography. Blood pressure, heart rate, cardiac output and hUII plasma concentrations were also measured. Forearm studies were repeated in five subjects with inhibition of endothelial mediators using aspirin and a "nitric oxide clamp". Dorsal hand vein diameter was determined by a standard displacement technique in response to local administration of hUII (3–300 pmol min–1) with and without nitric oxide synthase inhibition. Results: There was no significant change in FBF during brachial infusion of saline or hUII (dose range, 0.001 to 300 pmol min–1). A nitric oxide clamp did not unmask vasoactive effects of hUII. Human UII infusions (100 and 300 pmol min–1) significantly increased plasma hUII concentrations from baseline (12±3 pmol l–1) to 106±15 and 307±98 pmol l–1, respectively. Despite high circulating hUII concentrations, no change was seen in systemic hemodynamics and ECGs were unchanged. Human UII had no effect on hand vein diameter (n=6). Conclusions: In contrast to our hypothesised role of hUII, we found no vasoactive responses to hUII in vivo, consistent with recent in vitro studies in human blood vessels, but in contrast to non-human primate studies in vivo. Our data do not support a key role for hUII in the regulation of vascular tone and resting blood pressure in man. However, studies with hUII receptor antagonists are also needed before firm conclusions can be drawn.

KEYWORDS Arteries; Blood pressure; Hemodynamics; Regional blood flow; Veins


    1. Introduction
 Top
 Abstract
 1. Introduction
 2. Methods
 3. Results
 4. Discussion
 References
 
Human urotensin II (hUII) is a recently discovered vasoactive peptide hormone that acts as a high affinity ligand for rat G-protein receptor 14 (GPR14) [1–3] and the more recently discovered human receptor [3]. It is the most potent arterial vasoconstrictor yet discovered and has a sustained effect in blood vessels from a variety of species [2,4,5].

Human UII was first isolated in man from subgroups of motor neurones in the spinal cord [1]. Outside the CNS, the kidney has the highest expression of prepro hUII mRNA and, therefore, appears the most likely source of circulating hUII [3]. Its receptor distribution has been mapped using immuno-histochemistry, confirming target binding sites for hUII in cardiovascular tissues including coronary arteries, internal mammary arteries and ventricular cardiomyocytes [2,4]. Thus, it is likely that circulating hUII functions as an endocrine hormone. In vitro animal data and studies in rats and non-human primates in vivo, indicate that hUII is a potent vasoconstrictor and influences cardiac function [2,4]. However, conflicting results have been obtained from human blood vessels in vitro [4–6]. Although some studies suggest that hUII is 28- to 50-fold more potent than endothelin-1 (ET-1) [2,4], others show hUII to be a vasodilator [6]. In addition, there is some variability in response to hUII amongst species [7], depending on vessel location and type, and between individual preparations. This is highlighted by some of the in vitro studies having responding and non-responding vessels [5]. Interestingly, in the rat, the activity of hUII is most marked in the region of the proximal aorta, decreasing rapidly further down the arterial tree [4]. Venoconstriction has been found only in some studies in vessels from non-human primates and humans and, in contrast to the effects of ET-1 and norepinephrine, where present, hUII is less potent in veins than arteries [2,4].

To date, there have been no in vivo physiological studies of the actions of hUII in man. On the basis of animal in vivo and the positive human in vitro studies, we hypothesised that hUII would cause arteriolar vasoconstriction in the human forearm, but have little or no effect in veins. We also anticipated that systemic dosing would raise peripheral resistance and, hence, blood pressure. Our aim was to undertake the first human in vivo study with hUII, addressing local responses in human arterial vessels and dorsal hand veins. Subsequently, we explored the effect of higher doses on systemic haemodynamics and plasma hUII concentrations.


    2. Methods
 Top
 Abstract
 1. Introduction
 2. Methods
 3. Results
 4. Discussion
 References
 
These studies were conducted with the approval of the local research ethics committee and the written informed consent of each subject. The investigation conforms to the principles of the Declaration of Helsinki.

2.1 Subjects
Fifteen healthy men, mean age 37±4 years (range 22–53), were recruited from a bank of community volunteers held by the Clinical Research Centre at the Western General Hospital in Edinburgh. Four subjects took part in pilot studies and 11 in the definitive vein and forearm studies. Subjects were asked to fast from midnight before each study, and to abstain from caffeine containing drinks, alcohol and smoking over the preceding 24 h. Subjects’ mean height was 176±3 cm (range 170–180) and mean weight was 80±8 kg (range 63–92).

2.2 Drugs
All drugs were freshly prepared aseptically and dissolved in either saline (0.9% Baxter Healthcare Ltd., Norfolk, UK) or Gelofusine® (Braun Healthcare Ltd., Sheffield, UK). The drugs used were: hUII (Peptide Institute, Osaka, Japan, and SmithKline Beecham, PA, USA), angiotensin II (ANGII; Clinalfa, Laufelfingen, Switzerland), norepinephrine (NE; Abbott Laboratories, Kent, UK), sodium nitroprusside (SNP; David Bull Laboratories, Warwick, UK) and L-NG-monomethylarginine (L-NMMA; Clinalfa).

We confirmed the authentic nature of the hUII from both sources by high performance liquid chromatography and microsequencing (in the laboratory of Drs. S.A. Douglas and E.H. Ohlstein, SmithKline Beecham). We also confirmed the biological activity of the hUII peptides by showing the anticipated responses, and potency, in the rat proximal aorta (data not shown).

2.3 Forearm blood flow
Studies were performed with subjects resting supine, in a quiet clinical laboratory, maintained at a constant temperature of 22–24°C. The brachial artery of the non-dominant arm was cannulated with a 27-gauge steel needle (Cooper's Needle Works) under local anesthesia (1% lignocaine; Astra Pharmaceuticals Ltd., Hertfordshire, UK). This was connected to a constant rate infusion pump (IVAC) via a 16-gauge epidural catheter (Portex, UK). Saline was infused at 1 ml min–1 for a period of 30 min before drug infusion protocols were started to ensure a stable baseline. The total infusion rate was kept constant at 1 ml min–1. Throughout the study FBF was measured simultaneously in both arms by venous occlusion plethysmography [8,9], as previously described [10]. FBF was measured over a 3 min period every 6 min, and the last five recordings of FBF were averaged to determine flow in each arm.

2.4 Hand vein studies
Studies were performed with the subject resting semi-recumbent in a quiet clinical laboratory maintained at a constant temperature between 24 and 26°C. Studies were carried out in accordance with our previously described methodology using a standard displacement technique [11,12]. A 2 cm length of non-branching dorsal hand vein was cannulated in the direction of flow. A tripod was placed 1.5 cm proximal to the cannulation site as described in more detail previously by Aellig [11]. Saline was infused at a rate of 0.25 ml min–1 for 30 min to allow baseline measurements of vein diameter to be made. The total infusion rate was kept constant at 0.25 ml min–1 throughout the study.

2.5 Hemodynamics
Blood pressure (BP) was recorded over the brachial artery in the non-infused arm using a validated oscillometric sphygmomanometer (HEM 705CP, Omron, Japan) [13]. Cardiac index (CI) was assessed using a validated [14] transthoracic electrical bioimpedance technique (NCCOM3, BoMed, Irvine, CA, USA). Both BP and CI were recorded after each FBF recording was completed. Mean arterial pressure was defined as diastolic pressure plus 1/3 of the pulse pressure. Peripheral vascular resistance (PVR) was calculated as MAP divided by CI and expressed in arbitrary units. Throughout the study continuous electrocardiographic (ECG) monitoring was employed and a full 12-lead ECG recorded at baseline and at the end of the highest UII infusion rate on each study day.

2.6 Plasma urotensin II levels
Plasma hUII concentrations were determined by radioimmunoassay using rabbit anti-flounder UII antibody and hUII iodinated by the Iodogen method of Fraker and Speck [15]. The antibody had equal specificity for human and flounder UII, and there was no cross-reactivity in the assay with ET-1, ANGII or somatostatin-14 (Sigma, UK). Before assay, plasma samples were subject to reverse-phase chromatographic purification using Sep-Pak C18 cartridges (Millipore, UK) with acetonitrile solvent. The assay protocol was based on that previously described for flounder UII [16]. Briefly, sample extract was incubated with antibody (38,400 dilution) and 125I hUII at 4°C for 24 h. Following this, the complexes formed were precipitated by the addition of bovine {nu}-globulin (Sigma) and polyethylene glycol (Sigma), and the bound fraction was counted for 10 min in a gamma counter (1275 minigamma, Wallac, Finland). A typical standard curve for the hUII radio-immunoassay is shown in Fig. 1. Also shown is the parallelism of serial dilutions of human plasma extract with the standard curve established for synthetic hUII, confirming the specificity of the assay and its suitability for measurement of plasma hUII. Recovery of hUII in plasma extracts was 63% and intra- and inter-assay coefficients of variation in our laboratory were 7.6 and 13.3%, respectively; the sensitivity of the assay was 1 fmol hUII ml–1 plasma.


Figure 1
View larger version (29K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Fig. 1 Typical radio-immunoassay curve for hUII, with antibody bound 125-I hUII for increasing standard concentrations of synthetic hUII expressed as percent of the maximum label binding (Bo) measured in the zero standard tubes. Also shown is antibody bound label for assay tubes containing serial dilutions of human plasma extract. The parallelism of the two curves confirms the specificity of the assay for hUII and its suitability for plasma hUII measurements.

 
2.7 Study protocols
2.7.1 Pilot studies
Human UII (Peptide Institute, Osaka, Japan), diluted in 0.9% saline vehicle, was given intra-arterially on three separate occasions, each in two subjects, at rates of 0.001, 0.003 and 0.01 pmol min–1, 0.03, 0.1 and 0.3 pmol min–1, and 1, 10 and 30 pmol min–1. After 30 min saline run-in, each dose of hUII was given for 20 min.

2.7.2 Study 1: local arterial and systemic hemodynamics
On two occasions, separated by 1 week, each subject received a 30 min infusion of saline and then either hUII (Peptide Institute) or saline in a single-blind, randomised manner. Four subjects received 30 and 100 pmol min–1 hUII, and six subjects 100 and 300 pmol min–1 hUII. Each rate was maintained for a total of 20 min and FBF recorded at 3, 9 and 15 min. After the final FBF recording during saline baseline infusions and each dose increment, systemic hemodynamic measurements were made (heart rate, BP and CI) and 10 ml of venous blood was collected for determination of plasma hUII concentration. In addition, FBF studies were repeated in some of the same subjects. First, we used an alternative batch of hUII (SmithKline Beecham; dose range 0.1, 1, 10, 30 pmol min–1: six subjects). Second, we used an alternative Gelofusine® vehicle with the original hUII (Peptide Institute; dose range 1, 3, 30, 300 pmol min–1: four subjects).

2.7.3 Study 2: local arterial hemodynamics with inhibition of endothelial mediators
Five of the subjects who took part in Study 1 underwent a further study involving a "nitric oxide clamp" [17]. First, saline was infused for 30 min, and followed by L-NMMA infused intra-arterially at 4 µmol min–1 to block endogenous nitric oxide (NO) generation [18]. FBF was then restored to within ±10% of baseline by the co-infusion of SNP, an endothelium-independent NO donor (mean dose 0.6 nmol min–1, range 0.3–1.0). To produce a simultaneous inhibition of prostanoid production, each subject received 600 mg aspirin dissolved in 200 ml of water 30 min before the study. At this dose, aspirin inhibits bradykinin-stimulated endothelial prostacyclin generation and platelet thromboxane production [19], but has no direct effect on BP or basal vascular tone. Once FBF had returned to basal levels, hUII was co-infused at 1, 10 and 100 pmol min–1, each rate for 20 min. FBF and systemic haemodynamics were recorded as for Study 1.

2.7.4 Study 3: venous tone
Six subjects made two visits, separated by 1 week. Each received a 30 min infusion of saline into a selected dorsal hand vein followed by either L-NMMA (100 nmol min–1) or saline in a single-blind, randomised manner for 5 min. hUII was then co-infused at 3, 30 and 300 pmol min–1, each rate for 20 min. Saline was then infused for 10 min, followed by ANGII (25 ng min–1) for 3 min then saline for a further 10 min and finally NE (8 ng min–1) for 3 min to assess the integrity of the vein. Hand vein diameter was measured every 5 min after a 10 min baseline saline infusion. The total infusion rate was kept at 0.25 ml min–1.

2.8 Statistical analysis
All results are expressed as mean±S.E.M. Data for FBF have been expressed as percent change from baseline of the FBF ratio (derived from infused arm value divided by non-infused arm value). Repeated measures ANOVA was used to identify differences in FBF response between hUII and saline, hUII concentrations during placebo and drug infusion and in the vein studies between presence and absence of hUII and L-NMMA co-infusion. For single comparisons, data were analysed using paired Student's t-tests. Results were considered significant at P<0.05.


    3. Results
 Top
 Abstract
 1. Introduction
 2. Methods
 3. Results
 4. Discussion
 References
 
All subjects were symptom free throughout each study. Baseline FBF, heart rate, CI, BP, plasma hUII concentrations and vein diameter were similar on the different study days and there was no significant difference in the basal FBF between the infused and non-infused arms. Neither continuous single-lead ECG monitoring, nor the full 12-lead ECGs, revealed any changes during the three studies.

3.1 Pilot studies
There was no significant change in FBF in either arm, or systemic hemodynamics, during infusion of saline or hUII (data not shown).

3.2 Study 1
Baseline values for the non-infused and infused FBF were as follows: 3.5±0.9 and 4.5±2 ml 100 ml tissue–1 min–1, respectively, for Fig. 2A and 2.9±0.4 and 2.9±0.7 ml 100 ml tissue–1 min–1 for Fig. 2B. There was no significant change in FBF ratio during infusion of saline or hUII in either of the dose ranging studies (Fig. 2A and B). There was no significant change in systemic hemodynamics during infusion of hUII at any dose (Table 1A and B). However, there was a substantial and significant increase in circulating plasma hUII concentrations during hUII infusion (Fig. 3A and B). Studies with hUII diluted in Gelofusine® rather than saline, and UII from an alternative supplier (SmithKline Beecham), similarly did not change FBF or systemic hemodynamics (data not shown).


Figure 2
View larger version (28K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Fig. 2 (A) Mean percentage change in FBF ratio during 30 and 100 pmol min–1 UII infusion (bullet) compared with saline ({square}). ANOVA P=0.9 (n=4). (B) Mean percentage change in FBF ratio during 100 and 300 pmol min–1 UII infusion (bullet) compared with saline ({square}). ANOVA P=0.4 (n=6).

 

View this table:
[in this window]
[in a new window]

 
Table 1 Systemic hemodynamics during UII infusion in Study 1

 

Figure 3
View larger version (21K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Fig. 3 (A) Mean plasma concentration of hUII during 30 and 100 pmol min–1 UII infusion. **P<0.01 compared to baseline saline infusion (n=4). (B) Mean plasma concentration of hUII during 100 and 300 pmol min–1 UII infusion. *P<0.05, **P<0.01, ***P<0.001, Student's t-test compared to baseline saline infusion (n=6).

 
3.3 Study 2
Baseline values for non-infused and infused FBF were 3.1±0.3 and 3.2±0.5 ml 100 ml tissue–1 min–1, respectively. Infusion of L-NMMA resulted in a significant reduction in the FBF ratio (1±0.1 at baseline compared with 0.6±0.1; P=0.01 Student's t-test) (Fig. 4). Co-infusion of SNP (mean dose 0.6 nmol min–1, range 0.3 to 1.0) returned the FBF ratio to baseline (1±0.1 at baseline compared with 0.8±0.1, P=0.7 Student's t-test). There was no significant change in the FBF ratio, or FBF in either arm, during co-infusion of hUII following L-NMMA and SNP (FBF ratio, P=0.3). Human UII infusion did not significantly alter heart rate, systolic or diastolic blood pressure (P=0.8, P=0.8 and P=0.3, respectively, ANOVA).


Figure 4
View larger version (38K):
[in this window]
[in a new window]
[Download PowerPoint slide]
 
Fig. 4 Mean percentage change in the FBF ratio after co-infusion of L-NMMA (4 µmol min–1) and co-infusion of UII, *P=0.01 compared to baseline, Student's t-test. ANOVA for UII response was not significant, P=0.3 (n=5).

 
3.4 Study 3
Increasing doses of hUII had no significant effect on hand vein diameter compared with baseline (P=0.9, ANOVA) (Table 2). During co-infusion of hUII and L-NMMA, there was also no significant change in hand vein diameter (P=0.8, ANOVA). In contrast, ANGII and NE both induced a substantial venoconstriction (see Table 2). The response to ANGII and NE was slightly higher during L-NMMA co-administration, but these differences from the response with L-NMMA were not significant (P=0.8 and P=0.2, respectively, Student's t-test).


View this table:
[in this window]
[in a new window]

 
Table 2 Percentage change in hand vein diameter during UII infusion with and without co-infusion of L-NMMA in Study 3

 

    4. Discussion
 Top
 Abstract
 1. Introduction
 2. Methods
 3. Results
 4. Discussion
 References
 
The principal finding in these human in vivo studies is that infusion of hUII has no effect on arterial or venous tone, or on systemic hemodynamics. In addition, combined inhibition of NO and prostanoid production did not reveal any vasoactive effects of hUII in the forearm arteries or dorsal hand veins. We established the authentic nature of the hUII by microsequencing and by showing that it was pharmacologically active in vitro. Furthermore, substantial and consistent increases in plasma concentrations of hUII confirmed its delivery to the local and systemic circulation.

In isolated human arteries in vitro, Maguire et al. [4] demonstrated that hUII receptors are present in vascular smooth muscle layers. In addition, they showed a positive response to hUII where the potency of hUII in coronary, mammary and radial arteries was 50-fold greater than ET-1. However, there were differences in the characteristics of the responses. The maximal responses to ET-1 were consistently greater than those to hUII, and 30% of the arteries failed to respond to hUII, whereas all responded to ET-1. Recently, Hillier et al. [20] examined a wide range of human arteries and veins of differing calibre in vitro, and found no effect of hUII. The reason for this is not yet clear. Ames et al. performed a detailed in vivo study of the systemic hemodynamic response to hUII in non-human primates [2]. At lower systemic doses of hUII, Ames observed positive inotropism, whereas at higher doses hUII induced ischaemic myocardial dysfunction and extreme rises in peripheral resistance. On the basis of early human in vitro and the in vivo cynomolgus monkey data, we hypothesised that hUII would cause constriction of resistance vessels of the human forearm and raise blood pressure. Based on a FBF of 50 ml min–1 and an infusion rate of 300 pmol min–1, the estimated local plasma concentration of hUII in the infused arm in our study would be 6 nmol l–1, similar to those causing vasoconstriction in human in vitro studies [4]. Nevertheless, we found no effect of hUII at 300 pmol min–1 for 20 min in either the brachial artery or dorsal hand vein. This contrasts markedly with the local vascular responses in humans to other paracrine and endocrine mediators, such as ET-1 and ANGII, both of which cause ~40% reduction in FBF at only 5 pmol min–1 [21,22], and suggests that hUII does not play an important role in regulating peripheral vascular tone.

Indeed, during intra-arterial infusion of ANGII, a 10-fold increase in plasma concentrations of ANGII in the non-infused arm caused mean arterial pressure to rise by ~15 mmHg [23], whereas 30-fold increases in plasma hUII had no effect.

In any negative study it is important to consider the possibility that a real effect on arteriolar tone was missed. This is particularly important given the variability in the responses of isolated human vessels to hUII [4,6,7,20]. This is unlikely to be the case because there was no suggestion of groups of responders and non-responders from the 15 subjects who received hUII over a wide range of doses. In addition, brachial infusion studies are an extremely powerful tool for detecting vasoactive responses, usually requiring no more than six subjects to have a high degree of confidence in showing statistically significant effects [9].

Previously, Gibson found that fish urotensin II caused endothelium dependent vasodilatation at low dose, prior to vasoconstriction, in rat aortic tissue [24]. This raised the possibility that hUII may induce activation of NOS and subsequent release of NO. To date, only one in vitro study has studied the influence of NOS on responses to hUII [5], using L-N-nitro-arginine methylester (L-NAME) to inhibit NOS in isolated pulmonary vessels [5]. L-NAME increased maximal responses but not potency of hUII in rat main pulmonary artery. L-NAME also enhanced maximal responses to hUII in human pulmonary arteries, though only three of 10 vessels responded to hUII, and then only with very variable contractions. In the current studies, NO and prostanoid production were inhibited, using standard techniques. Even so, we were unable to unmask vasoconstriction to hUII in either human resistance or capacitance vessels in vivo.

The lack of response of resistance vessels in vivo may be due to low receptor density or poor coupling to signal transduction mechanisms at this site, perhaps as part of inter-species variation. The proximal aorta seems to be most sensitive to hUII and it is possible that subtle effects on large arteries are caused by hUII but not detected using routine hemodynamic assessment. The in vivo effects of hUII on human large arteries merits further investigation. A possible alternative explanation for the lack of effects of hUII is high receptor occupancy. Studies with hUII antagonists in vivo can address this issue, and should allow the physiological role of hUII in man to be more clearly defined. In conclusion, we have found no evidence of local or systemic hemodynamic effects of hUII in vivo despite infusion of hUII at doses that increase plasma concentrations 30-fold.

Time for primary review 27 days.


    Acknowledgements
 
Dr. Jonathan T. Affolter is a British Heart Foundation Junior Research Fellow (grant FS/2000021). Professor D.J. Webb was the recipient of a Research Leave Fellowship from the Wellcome Trust (WT 0526330) at the time of the study. Our thanks go to Neil Johnston and Fiona Strachan for technical support and data collection. We are grateful to Drs Steve Douglas and Eliot Ohlstein at SmithKline Beecham, PA, USA for their help in the authentication of the different batches of hUII. We are grateful to Dr. Ian Megson for confirming the biological activity of hUII in the rat proximal aorta.


    Notes
 
2 Present address: Cardiologia, Clinica San Carlo, via Ospedale 21, Paderno Dugnano, Milano, Italy. Back

1 Present address: Clinical Pharmacology Unit, Addenbrooke's Hospital, University of Cambridge, Cambridge CB2 2QQ, UK. Back


    References
 Top
 Abstract
 1. Introduction
 2. Methods
 3. Results
 4. Discussion
 References
 

  1. Coulouarn Y., Lihrmann I., Jegou S., et al. Cloning of the cDNA encoding the urotensin II precursor in frog and human reveals intense expression of the urotensin II gene in motorneurones of the spinal cord. Proc. Natl. Acad. Sci. USA (1997) 95:15803–15808.[CrossRef]
  2. Ames R.S., Sarau H.M., Chambers J.K., et al. Human urotensin II is a potent vasoconstrictor and agonist for the orphan receptor GPR14. Nature (1999) 401:282–286.[CrossRef][Medline]
  3. Nothacker H.P., Wang Z., McNeil A.M., et al. Identification of the natural ligand of an orphan G-protein-coupled receptor involved in the regulation of vasoconstriction. Nat. Cell Biol. (1999) 1:383–385.[CrossRef][Web of Science][Medline]
  4. Maguire J.J., Kuc R.E., Davenport A.P. Orphan-receptor ligand human urotensin II: receptor localisation in human tissues and comparison of vascular responses with endothelin-1. Br. J. Pharmacol. (2000) 131:441–446.[CrossRef][Web of Science][Medline]
  5. MacLean M.R., Alexander D., Stirrat A., et al. Contractile responses to human urotensin II in rat and human pulmonary arteries: effect of endothelial factors and hypoxia in the rat. Br. J. Pharmacol. (2000) 130:201–204.[CrossRef][Web of Science][Medline]
  6. Stirrat A., Gallagher M., Douglas S.A., et al. Potent vasodilator responses to human urotensin-II in human pulmonary and abdominal resistance arteries. Am. J. Physiol. Heart Circ. Physiol. (2001) 280:H925–H928.[Abstract/Free Full Text]
  7. Douglas S.A., Sulpizio A.C., Piercy V., et al. Differential vasoconstrictor activity of human urotensin II in vascular tissue isolated from the rat, mouse, dog, pig, marmoset and cynomolgus monkey. Br. J. Pharmacol. (2000) 131:1262–1274.[CrossRef][Web of Science][Medline]
  8. Whitney R.J. The measurement of volume changes in human limbs. J. Physiol. (1953) 21:1–27.[Medline]
  9. Benjamin N., Calver A., Collier J., et al. Measuring forearm blood flow and interpreting the responses to drugs and mediators. Hypertension (1995) 25:918–923.[Abstract/Free Full Text]
  10. Love M.P., Haynes W.G., Gray G.A., Webb D.J., McMurray J.J.V. Vasodilator effects of endothelin-converting enzyme inhibition and endothelin ETA receptor blockade in chronic heart failure patients treated with ACE inhibitors. Circulation (1996) 94:2131–2137.[Abstract/Free Full Text]
  11. Aellig W.H. A new technique for recording compliance of human hand veins. Br. J. Clin. Pharmacol. (1981) 11:237–243.[Web of Science][Medline]
  12. Webb D.J., Haynes W.G. Venoconstriction to endothelin-1 in humans is attenuated by local generation of prostacyclin but not nitric oxide. J. Cardiovasc. Pharmacol. (1993) 22(S8):S317–S320.[Web of Science][Medline]
  13. O'Brien E., Mee F., Atkins N., Thomas M. Evaluation of three devices of blood pressure according to the revised British Hypertension Society Protocol: the Omron HEM-705CP, Philips HP5332 and Nissei DS-175. Blood Press. Monit. (1996) 1:55–61.[Medline]
  14. Northridge D.B., Findlay I.N., Wilson J., Henderson E., Dargie H.J. Non-invasive determination of cardiac output by Doppler echocardiography and electrical bioimpedance. Br. Heart J. (1990) 63:93–97.[Abstract/Free Full Text]
  15. Fraker P.J., Speck J.C. Protein and cell membrane iodinations with a sparingly soluble chloroamide, 1,3,4,6-tetrachloro-3a,6a-diphrenylglycoluril. Biochem. Biophys. Res. Commun. (1978) 80:849–857.[CrossRef][Web of Science][Medline]
  16. Winter M.J., Hubbard P.C., McCrohan C.R., Balment R.J. A homologous radioimmunoassay for the measurement of urotensin II in the euryhaline flounder, Platichthys flesus. Gen. Comp. Endocrinol. (1999) 114:249–256.[CrossRef][Web of Science][Medline]
  17. Verhaar M.C., Strachan F.E., Newby D.E., et al. Endothelin-A receptor antagonist mediated vasodilatation is attenuated by inhibition of nitric oxide synthesis and by endothelin-B receptor blockade. Circulation (1998) 97:752–756.[Abstract/Free Full Text]
  18. Vallance P., Collier J., Moncada S. Effect of endothelium derived nitric oxide on peripheral arteriolar tone. Lancet (1989) ii:997–999.
  19. Heavey D.J., Barrow S.E., Hickling N.E., Ritter J.M. Aspirin causes short-lived inhibition of bradykinin-stimulated prostacyclin production in man. Nature (1985) 318:186–188.[CrossRef][Medline]
  20. Hillier C., Berry C., Petrie M.C., et al. Effects of urotensin II in human arteries and veins of varying caliber. Circulation (2001) 103:1378–1381.[Abstract/Free Full Text]
  21. Clark J.G., Benjamin N., Larkin S.W., et al. Endothelin is a potent long-lasting vasoconstrictor in men. Am. J. Physiol. (1989) 257:H2033–H2035.[Web of Science][Medline]
  22. Haynes W.G., Webb D.J. Contribution of endogenous generation of endothelin-1 to basal vascular tone in man. Lancet (1994) 344:852–854.[CrossRef][Web of Science][Medline]
  23. Labinjoh C., Newby D.E., Dawson P., et al. Fibrinolytic actions of intra-arterial angiotensin II and bradykinin in vivo in man. Cardiovasc. Res. (2000) 47:707–714.[Abstract/Free Full Text]
  24. Gibson A. Complex effects of Gillichthys urotensin II on rat aortic strips. Br. J. Pharmacol. (1987) 91:205–212.[Web of Science][Medline]

Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Br J AnaesthHome page
A. D. Leonard, J. P. Thompson, E. L. Hutchinson, S. P. Young, J. McDonald, J. Swanevelder, and D. G. Lambert
Urotensin II receptor expression in human right atrium and aorta: effects of ischaemic heart disease
Br. J. Anaesth., April 1, 2009; 102(4): 477 - 484.
[Abstract] [Full Text] [PDF]


Home page
Am. J. Physiol. Renal Physiol.Home page
A. E. S. Abdel-Razik, R. J. Balment, and N. Ashton
Enhanced renal sensitivity of the spontaneously hypertensive rat to urotensin II
Am J Physiol Renal Physiol, October 1, 2008; 295(4): F1239 - F1247.
[Abstract] [Full Text] [PDF]


Home page
Br J AnaesthHome page
J. P. Williams, J. P. Thompson, S. P. Young, S. J. Gold, J. McDonald, D. J. Rowbotham, and D. G. Lambert
Nociceptin and urotensin-II concentrations in critically ill patients with sepsis
Br. J. Anaesth., June 1, 2008; 100(6): 810 - 814.
[Abstract] [Full Text] [PDF]


Home page
Eur J Heart FailHome page
S. Kruger, J. Graf, D. Kunz, T. Stickel, M. W. Merx, P. Hanrath, and U. Janssens
Urotensin II in patients with chronic heart failure
Eur J Heart Fail, June 1, 2005; 7(4): 475 - 478.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Wilkinson, I. B
Right arrow Articles by Webb, D. J
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Wilkinson, I. B
Right arrow Articles by Webb, D. J
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?