Skip Navigation

Cardiovascular Research 2002 53(2):292-293; doi:10.1016/S0008-6363(01)00567-3
© 2002 by European Society of Cardiology
This Article
Right arrow Extract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Sturek, M.
Right arrow Articles by Reddy, H. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sturek, M.
Right arrow Articles by Reddy, H. K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Copyright © 2001, European Society of Cardiology

New tools for prevention of restenosis could decrease the ‘oculo-stento’ reflex

Michael Stureka,b,c,* and Hanumanth K. Reddyb,c

aDepartment of Physiology, School of Medicine, MA415 Medical Sciences Building, University of Missouri, Columbia, MO 65212, USA
bDepartment of Internal Medicine, Division of Cardiology, School of Medicine, University of Missouri, Columbia, MO 65212, USA
cDiabetes & Cardiovascular Biology Program, School of Medicine, University of Missouri, Columbia, MO 65212, USA

* Corresponding author. Tel.: +1-573-882-2640 or 573-882-3787; fax: +1-573-884-4276 sturekm{at}missouri.edu

accepted 7 December 2001

KEYWORDS Restenosis; Stents; Angioplasty; Atherosclerosis

See article by Yasuda et al. [8] (pages 481–486) in this issue.

Restenosis remains the major challenge to percutaneous coronary intervention procedures, despite substantial improvements. Standard balloon angioplasty results in restenosis in 30–50% of patients within several months after successful revascularization [1], requiring repeat target vessel revascularization. Placement of stents effectively reduces early restenosis due to elastic recoil of the artery, but there is increased late restenosis due to excessive intimal hyperplasia, yielding an overall restenosis rate of about 20–30% [2]. Although this restenosis rate is higher than desired, stenting has become the main interventional procedure for treatment of flow-limiting atherosclerotic lesions. In our clinic and numerous others almost 60–70% of critical lesions are stented. This dominant procedure has prompted the colloquial coining of the ‘oculo-stento reflex’—an interventionalist sees a lesion and reflexively stents it.

Rapamycin-coated stents have virtually eliminated restenosis in early trials [3–5]. After 8 months of follow-up there have been no adverse events [3], thus if rapamycin-coated stents have long-term efficacy beyond these initial trials this method shows great promise. Drug-coated stents offer the practical means of controlling the dose and duration of these new drugs. Unlike polymeric stents, which had a potential to cause inflammation and thrombosis, the latest technique of dip-coating provides immediate delivery to the target vessel wall with minimal effects on adjacent tissue [6]. Cautious optimism is warranted regarding the long-term outcome of rapamycin-coated stents, however, as radiation-emitting stents were also touted as the ultimate cure when they were first introduced. Unfortunately, thrombosis, edge stenosis (‘candy wrapper’ effect), and other complications have limited the usefulness of radiation [7]. A major point is that 30–40% of critical lesions cannot be stented, largely because they occur at branch sites or in small arteries of <3 mm i.d. Hence, it must be appreciated that other methods for prevention of restenosis beyond the ‘oculo-stento reflex’ need continued development.

Yasuda et al. [8] in this issue address this need with compelling evidence that arterial restenosis can be prevented by catheter delivery of an anti-mitotic agent, not by stenting. The results of the study are dramatic and convincing. Rabbits were subjected to classical injury of the iliac artery elicited by over-inflation of a balloon. Local delivery of the microtubule polymerizing agent docetaxel virtually eliminated restenosis measured 28 days post-balloon injury. Solid evidence for the anti-mitotic mechanism of docetaxel was provided by the 67% decrease in proliferation measured as the reduction in Ki-67-labeled cells. Taxoid microtubule polymerizing agents are widely used as anti-cancer drugs and the major side effect of systemic use, leukocytopenia, is well-documented [9]. Yasuda et al. show that docetaxel did not reduce leukocyte number over the 28-day study, indicating that local application of cytotoxic drugs is without systemic side effects. Finally, blood flow was maintained adequately to the distal limb during the relatively long duration (20 min) local delivery of docetaxel using their specialized catheter. A potentially negative outcome is that long-term local tissue events may translate into arterial dilation, aneurysm promotion, and arterial rupture [10]. Note that a common feature of rapamycin studies using stents [3–5] and Yasuda's work is the use of anti-proliferative agents, thus providing sound rationale for continued focus on development of anti-proliferative pharmacological agents.

An excellent study sometimes raises more questions than it answers and provides a stimulus for additional research. In particular, several needs emerge from the excellent study of Yasuda et al. [8]. (1) Restenosis studies on therapeutic efficacy and, especially, basic cellular and molecular mechanisms, should be conducted on large animal models that better mimic the development of atherosclerotic lesions, e.g. primates and swine. The recent review of Johnson et al. [11] provides a wealth of information regarding limitations of rodent models of restenosis. A related issue is that mechanisms of restenosis must be studied in animal models having unique, accelerated coronary artery disease, such as in diabetes [12–14]. (2) Catheter delivery techniques that will enable presentation of pharmacological agents to the coronary circulation without limiting flow [15–18] must be refined. Although Yasuda's specially designed local delivery catheter minimized ischemic insult to the limb (skeletal muscle) [15], there is limited evidence that catheters can be used for coronary interventions where ischemia–reperfusion injury would be much more serious. Local delivery of the drug at the lesion site is fraught with a number of problems; namely, drug to target contact, duration of action, and remote side-effects due to immediate wash-out. Thus, coupling of efforts in pharmacology with interventional device technology seems essential. (3) Perhaps the most urgent need is the study of these pharmacological agents with interventional device technology in naturally occurring atherosclerotic lesions, rather than balloon injured healthy arteries. Application of the findings to restenosis in humans could be limited because restenosis is studied after injury of normally, healthy arteries, rather than after angioplasty of mature, natural atherosclerotic lesions.

In conclusion, promising results of Yasuda et al. [8] and other anti-proliferative therapy [3–5] strongly indicate that coupling of pharmacology with interventional device technology for prevention of restenosis could add another dimension beyond the ‘oculo-stento reflex’. Is it possible that utilization of all devices coupled with pharmacotherapy will cure restenosis?


    References
 Top
 References
 

  1. Popma J.J., Califf R.M., Topol E.J. Clinical trials of restenosis after coronary angioplasty. Circulation (1991) 84:1426–1436.[Free Full Text]
  2. Kuntz R.E., Baim D.S. Prevention of coronary restenosis: the evolving evidence base for radiation therapy. Circulation (2000) 101:2130–2133.[Free Full Text]
  3. Sousa J.E., Costa M.A., Abizaid A., et al. Lack of neointimal proliferation after implantation of sirolimus-coated stents in human coronary arteries. Circulation (2001) 103:192–195.[Abstract/Free Full Text]
  4. Sousa J.E., Costa M.A., Abizaid A., et al. Mid- (4 month) and long-term (1 year) QCA and three dimensional IVUS followup after implantation of sirolimus-coated stent in human coronary arteries. J Am Coll Cardiol (2001) 37(Suppl_A):8A.
  5. Feres F., Costa M.A., Abizaid A. Comparison between sirolimus-coated and noncoated stent implantation in human coronary arteries. J Am Coll Cardiol (2001) 37(Suppl A):47A.
  6. Van der Giessen W.J., Lincoff A.M., Schwartz R.S., et al. Marked inflammatory sequelae to implantation of biodegradable and nonbiodegradable polymers in porcine coronary arteries. Circulation (1996) 94:1690–1697.[Abstract/Free Full Text]
  7. Waksman R. Late thrombosis after radiation: sitting on a time bomb. Circulation (1999) 100:780–782.[Free Full Text]
  8. Yasuda S., Noguchi T., Gohda M., et al. Local delivery of low-dose docetaxel, a novel microtubule polymerizing agent, reduces neointimal hyperplasia in a balloon-injured rabbit illiac artery model. Cardiovasc Res (2002) 53:481–486.[Abstract/Free Full Text]
  9. Garcia P., Braguer D., Carles G., et al. Comparative effects of taxol and Taxotere on two different human carcinoma cell lines. Cancer Chemother Pharmacol (1994) 34:335–343.[Web of Science][Medline]
  10. Sriram V., Patterson C. Cell cycle in vasculoproliferative diseases: potential interventions and routes of delivery. Circulation (2001) 103:2414–2419.[Abstract/Free Full Text]
  11. Johnson G.J., Griggs T.R., Badimon L. The utility of animal models in the preclinical study of interventions to prevent human coronary artery restenosis: Analysis and recommendations. Thromb Haemost (1999) 81:835–843.[Web of Science][Medline]
  12. Dixon J.L., Stoops J.D., Parker J.L., et al. Dyslipidemia and vascular dysfunction in diabetic pigs fed an atherogenic diet. Arterioscler Thromb Vasc Biol (1999) 19:2981–2992.[Abstract/Free Full Text]
  13. Sturek M., Otis C., Wamhoff B.R., et al. Dyslipidemia, not hyperglycemia, is the main factor eliciting coronary artery disease in Yucatan swine. Abstract, Arterioscler Thromb Vasc Biol (2001) 21:644.
  14. Gerrity R.G., Natarajan R., Nadler J.L., Kimsey T. Diabetes-induced accelerated atherosclerosis in swine. Diabetes (2001) 50:1654–1665.[Abstract/Free Full Text]
  15. Noguchi T., Yasuda S., Itoh T., et al. A new multifunctional percutaneous transluminal coronary angioplasty catheter device capable of balloon inflation, local drug delivery and coronary perfusion. J Cardiol (2000) 35:41–45.[Medline]
  16. Varenne O., Gerard R.D., Sinnaeve P., et al. Percutaneous adenoviral gene transfer into porcine coronary arteries: Is catheter-based gene delivery adapted to coronary circulation? Hum Gene Ther (1999) 10:1105–1115.[CrossRef][Web of Science][Medline]
  17. Landau C., Pirwitz M.J., Willard M.A., et al. Adenoviral mediated gene transfer to atherosclerotic arteries after balloon angioplasty. Am Heart J (1995) 129:1051–1057.[CrossRef][Web of Science][Medline]
  18. Palasis M., Luo Z., Barry J.J., Walsh K. Analysis of adenoviral transport mechanisms in the vessel wall and optimization of gene transfer using local delivery catheters. Hum Gene Ther (2000) 11:237–246.[CrossRef][Web of Science][Medline]

Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Cardiovasc ResHome page
J. M. Edwards, Z. P. Neeb, M. A. Alloosh, X. Long, I. N. Bratz, C. R. Peller, J. P. Byrd, S. Kumar, A. G. Obukhov, and M. Sturek
Exercise training decreases store-operated Ca2+entry associated with metabolic syndrome and coronary atherosclerosis
Cardiovasc Res, October 4, 2009; (2009) cvp308v2.
[Abstract] [Full Text] [PDF]


Home page
CirculationHome page
P. A. Kingston, S. Sinha, C. E. Appleby, A. David, T. Verakis, M. G. Castro, P. R. Lowenstein, and A. M. Heagerty
Adenovirus-Mediated Gene Transfer of Transforming Growth Factor-{beta}3, but Not Transforming Growth Factor-{beta}1, Inhibits Constrictive Remodeling and Reduces Luminal Loss After Coronary Angioplasty
Circulation, December 2, 2003; 108(22): 2819 - 2825.
[Abstract] [Full Text] [PDF]


This Article
Right arrow Extract Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Sturek, M.
Right arrow Articles by Reddy, H. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sturek, M.
Right arrow Articles by Reddy, H. K.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?