Skip Navigation

Cardiovascular Research 2000 45(1):13-21; doi:10.1016/S0008-6363(99)00252-7
© 2000 by European Society of Cardiology
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Prinzen, F. W
Right arrow Articles by Bassingthwaighte, J. B
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Prinzen, F. W
Right arrow Articles by Bassingthwaighte, J. B
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Copyright © 2000, European Society of Cardiology

Blood flow distributions by microsphere deposition methods

Frits W Prinzena,* and James B Bassingthwaighteb

aDepartment of Physiology, Cardiovascular Research Institute Maastricht, Maastricht University, P.O. Box 616, 6200 MD Maastricht, The Netherlands
bDepartment of Biomedical Engineering, University of Washington, Seattle, WA 98195, USA

* Corresponding author. Tel.: +31-43-388-1200; fax: +31-43-367-1028 frits.prinzen{at}fys.unimaas.nl

The art and science of the use of deposition markers for the estimation of blood flow distributions throughout the body and within organs is reviewed. Development of diffusible tracer techniques started 50 years ago. Twenty years later, radioactive 15 micron microspheres became the standard marker. Early studies on small animals, fetal sheep in 1967 and rats in 1976, provoked much of the technical development. Needs for avoiding the use of radioactivity, for having long lasting labels, and for providing higher spatial resolution, are driving the continuing exploration of newer techniques using colored and fluorescent microspheres and molecular deposition markers. Strengths and weaknesses of the various methods are compared.

KEYWORDS Blood flow; Flow heterogeneity; Cardiac output; Deposition markers; Rats; Mice; Dogs


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
RadiologyHome page
M. Oostendorp, M. J. Post, and W. H. Backes
Vessel Growth and Function: Depiction with Contrast-enhanced MR Imaging
Radiology, May 1, 2009; 251(2): 317 - 335.
[Abstract] [Full Text] [PDF]


Home page
Eur J Heart FailHome page
H.-F. Tse, C.-W. Siu, S.-G. Zhu, L. Songyan, Q.-Y. Zhang, W.-H. Lai, Y.-L. Kwong, J. Nicholls, and C.-P. Lau
Paracrine effects of direct intramyocardial implantation of bone marrow derived cells to enhance neovascularization in chronic ischaemic myocardium
Eur J Heart Fail, August 1, 2007; 9(8): 747 - 753.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.