Skip Navigation

Cardiovascular Research 1999 44(3):549-555; doi:10.1016/S0008-6363(99)00255-2
© 1999 by European Society of Cardiology
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Power, J.M
Right arrow Articles by Alferness, C.A
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Power, J.M
Right arrow Articles by Alferness, C.A
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Copyright © 1999, European Society of Cardiology

Passive ventricular constraint amends the course of heart failure: a study in an ovine model of dilated cardiomyopathy

J.M Powera,*, J Ramanb, A Dornoma, S.J Farishc, L.M Burrella, A.M Tonkina, B Buxtonb and C.A Alfernessd

aDepartment of Medicine, University of Melbourne (Austin and Repatriation Medical Centre Campus), Melbourne, Australia
bDepartment of Cardiothoracic Surgery, University of Melbourne (Austin and Repatriation Medical Centre Campus), Melbourne, Australia
cDepartment of Public Health and Community Medicine, University of Melbourne (Parkville Campus), Melbourne, Australia
dAcorn Cardiovascular Inc., St. Paul, MN, USA

* Corresponding author. Tel.: +61-3-9496-4090; fax: +61-3-9496-4099 jmp{at}austin.unimelb.edu.au

Objective: Dilated cardiomyopathy (DCM) is associated with a progressive deterioration in cardiac function. We hypothesised that some of the deleterious effects of DCM could be reduced by mechanically limiting the degree of cardiac dilatation. Methods: A Transonic 20A cardiac output (CO) flow-probe was implanted in the pulmonary artery of 12 adult (52±4 kg) sheep. Early heart failure was created by rapid right ventricular (RV) pacing for 21 days at a rate which resulted in an initial 10% decrease in CO (to a maximum of 190 bpm). A custom polyester jacket (Acorn Cardiovascular, St Paul, MN) was then placed, via a partial lower sternotomy, on the ventricular epicardium of all sheep. Animals were randomised either to jacket retention (wrap) or removal (sham). Pacing was recommenced at a higher rate (that initiated a further 10% decrease in CO) for 28 days. Haemodynamic and echocardiographic parameters were determined at baseline, implant and at termination. Results: At termination, the left ventricular fractional shortening was significantly higher (p=0.03), the degree of mitral valve regurgitation lower (scaled 0–3) (p=0.03) and the left ventricular long axis area smaller (p=0.02) in the wrap animals compared with sham. Conclusions: In this model of heart failure, ventricular constraint with a polyester jacket diminished the deterioration in cardiac function associated with progressive dilated cardiomyopathy. These results suggest that maintainance of a more normal cardiac size and shape may be beneficial in patients with dilated cardiomyopathy.

KEYWORDS Heart failure; Cardiomyopathy; Ventricular function; Remodelling


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
ICVTSHome page
F. Bredin, J. Liska, and A. Franco-Cereceda
Changes in natriuretic peptides following passive containment surgery in heart failure patients with dilated cardiomyopathy
Interactive CardioVascular and Thoracic Surgery, February 1, 2009; 8(2): 191 - 194.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.