Skip Navigation

Cardiovascular Research 1999 44(2):436-448; doi:10.1016/S0008-6363(99)00220-5
© 1999 by European Society of Cardiology
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Galea, J
Right arrow Articles by Holt, C.M
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Galea, J
Right arrow Articles by Holt, C.M
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Copyright © 1999, European Society of Cardiology

Alterations in c-fos expression, cell proliferation and apoptosis in pressure distended human saphenous vein

J Galea1,a, J Armstrong1, S.E Francisa,a, G Cooperb, D.C Crossmana and C.M Holta,*

aCardiovascular Medicine, University of Sheffield, Clinical Sciences Centre, Northern General Hospital, Sheffield S5 7AU, UK
bCardiothoracic Surgery, Northern General Hospital, Sheffield S5 7AU, UK

* Corresponding author. Tel.: +44-114-271-4973; fax: +44-114-261-9587 c.holt{at}sheffield.ac.uk

Objectives: Saphenous vein graft failures, resulting from thrombosis and the abnormal proliferation, migration and apoptosis of vascular smooth muscle cells (VSMC) are major limitations of coronary artery bypass surgery. We investigated whether surgical trauma of human saphenous vein induces the early response gene c-fos and causes alterations in rates of proliferation and apoptosis. Methods: Surgically prepared human vein consisted of distended (at 350 mmHg for 2 min) or non-distended segments of vein maintained in serum free RPMI at 37°C and 5% CO2 for various time intervals. c-fos expression was detected by Northern analysis. Cell proliferation and apoptosis were determined by [3H]thymidine incorporation combined with proliferating cell nuclear antigen (PCNA) immunostaining and TUNEL, respectively. Labelling indices for proliferation and apoptosis were correlated with vessel wall thicknesses. Results: Control, freshly isolated vein expressed no c-fos. Surgically prepared vein synthesized c-fos 1 h following harvesting. There was a significant increase in c-fos in distended compared to non-distended vein. c-Fos protein increased in surgically prepared vein 24 h after harvesting. There was a significant increase in vascular cell proliferation in the non-distended compared to the distended vein: mean (S.E.M.) 1279 (218) vs. 863 (155) dpm/µg DNA, P<0.05, n=6. In addition, the apoptotic index was significantly lower in the media of non-distended vs. distended vein 0.82 (0.2) vs. 5.5 (1.5), P<0.05, n=5. Conclusions: These findings demonstrate that surgical preparation of human saphenous vein increases expression of c-fos mRNA and apoptosis and reduces proliferation when compared with non-distended vein. These changes may influence the failure of saphenous vein grafts.

KEYWORDS Apoptosis; Cardiovascular surgery; Gene expression; Smooth muscle; Veins


1 These authors have contributed equally to the manuscript.


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
T. Schachner, C. Steger, S. Heiss, N. Bonaros, W. Sterlacci, G. Laufer, and J. Bonatti
Paclitaxel treatment reduces neointimal hyperplasia in cultured human saphenous veins
Eur. J. Cardiothorac. Surg., December 1, 2007; 32(6): 906 - 911.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. Loesch, M. R. Dashwood, and M. S. Fernandez-Alfonso
Improved saphenous vein graft patency for coronary artery bypass grafting: "No-touch" harvesting or "dissection without touching"?
J. Thorac. Cardiovasc. Surg., September 1, 2007; 134(3): 819 - 820.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
K. Hinokiyama, G. Valen, S. Tokuno, J. B. Vedin, and J. Vaage
Vein graft harvesting induces inflammation and impairs vessel reactivity.
Ann. Thorac. Surg., October 1, 2006; 82(4): 1458 - 1464.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. R. Dashwood, K. Savage, A. Dooley, X. Shi-Wen, D. J. Abraham, and D. S.R. Souza
Effect of Vein Graft Harvesting on Endothelial Nitric Oxide Synthase and Nitric Oxide Production
Ann. Thorac. Surg., September 1, 2005; 80(3): 939 - 944.
[Abstract] [Full Text] [PDF]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
J. Cornelissen, J. Armstrong, and C. M. Holt
Mechanical Stretch Induces Phosphorylation of p38-MAPK and Apoptosis in Human Saphenous Vein
Arterioscler Thromb Vasc Biol, March 1, 2004; 24(3): 451 - 456.
[Abstract] [Full Text]


Home page
Ann. Thorac. Surg.Home page
M. Chello, P. Mastroroberto, G. Frati, G. Patti, A. D'Ambrosio, G. Di Sciascio, and E. Covino
Pressure distension stimulates the expression of endothelial adhesion molecules in the human saphenous vein graft
Ann. Thorac. Surg., August 1, 2003; 76(2): 453 - 458.
[Abstract] [Full Text] [PDF]


Home page
Cardiovasc ResHome page
J. H. Baron, A. H. Gershlick, K. Hogrefe, J. Armstrong, C. M. Holt, R. K. Aggarwal, M. Azrin, M. Ezekowitz, and D. P. de Bono
In vitro evaluation of c7E3-Fab (ReoProTM) eluting polymer-coated coronary stents
Cardiovasc Res, June 1, 2000; 46(3): 585 - 594.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.