Skip Navigation

Cardiovascular Research 1997 34(3):557-567; doi:10.1016/S0008-6363(97)00056-4
© 1997 by European Society of Cardiology
This Article
Right arrow Full Text Freely available
Right arrow FREE Full Text (PDF) Freely available
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Canham, P. B.
Right arrow Articles by Boughner, D. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Canham, P. B.
Right arrow Articles by Boughner, D. R.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Copyright © 1997, European Society of Cardiology

Contrasting structure of the saphenous vein and internal mammary artery used as coronary bypass vessels

Peter B. Canhama,*, Helen M. Finlaya and Derek R. Boughnera,b

aDepartment of Medical Biophysics, University of Western Ontario, and John P. Robarts Research Institute, London, Ont. N6A 5C1, Canada
bDepartment of Medicine, University of Western Ontario, and John P. Robarts Research Institute, London, Ont. N6A 5C1, Canada

* Corresponding author. Tel.: +1 (519) 661-3053; fax: +1 (519) 661-2123; e-mail: medbpa@uwoadmin.uwo.ca

Objectives: To report quantitatively on the three-dimensional layered organization of the collagen and smooth muscle component of the two most successful vessels for coronary bypass—the internal mammary artery (IMA) and the long saphenous vein (SV). Our aim was to provide an explanation for the differential structural stiffness of these two vessels (both functioning at arterial pressures in their new environment), and how they might be susceptible to endothelial thickening. Methods: Eleven human saphenous veins and 23 internal mammary arteries were fixed at arterial distending pressure of 110 mmHg, and were sectioned in cross-section at 7 µm thickness. A subset of these was also sectioned tangentially. Measurements of the three-dimensional alignment of collagen and smooth muscle fibers within the vessel wall were made using polarized light microscopy and the universal stage attachment. Data were plotted and analysed using circular statistics. Results: The IMA, structured like an elastic artery, is dominated by a media with discrete lamellae of wavy collagen and smooth muscle, aligned nearly circumferentially, with a low variability of alignment (mean circular SD 12°). The SV is more variable in its size and structure, characteristically with a narrow circumferential media comprised mostly of collagen which is straightened and highly aligned at arterial pressures (mean circular SD 9°). Circumferential collagen in the vein was often adjacent to longitudinal bundles of smooth muscle and collagen. Conclusions: The strikingly aligned structure of the SV complements the known high mechanical stiffness of this vessel when at arterial distending pressure. The high fraction of longitudinal muscle, in addition to the circumferential muscle cells in the SV make it vulnerable to any pre-implant surgical preparation, and to the cyclical luminal pressures and longitudinal strains characteristic for epicardial arteries.

KEYWORDS Human, saphenous vein; Human, arteries; Coronary artery bypass grafting; Collagen, orientation; Polarized light microscopy; Stereology


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?


This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
A. Jonsson, J. Jensen, A. Olsson, P. Holm, and J. Liska
Follow-Up of Patients Operated on With Arterial Patch Angioplasty of the Left Main Coronary Artery
Ann. Thorac. Surg., April 1, 2006; 81(4): 1249 - 1255.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
W. Stooker, M. Gok, P. Sipkema, H. W. M. Niessen, A. Baidoshvili, N. Westerhof, E. K. Jansen, C. R. H. Wildevuur, and L. Eijsman
Pressure-diameter relationship in the human greater saphenous vein
Ann. Thorac. Surg., November 1, 2003; 76(5): 1533 - 1538.
[Abstract] [Full Text] [PDF]


Home page
Arterioscler. Thromb. Vasc. Bio.Home page
M. Lauth, M.-M. Berger, M. Cattaruzza, and M. Hecker
Pressure-Induced Upregulation of Preproendothelin-1 and Endothelin B Receptor Expression in Rabbit Jugular Vein In Situ : Implications for Vein Graft Failure?
Arterioscler Thromb Vasc Biol, January 1, 2000; 20(1): 96 - 103.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. Liska, A. Jonsson, U. Lockowandt, I. Herzfeld, S. Gelinder, and A. Franco-Cereceda
Arterial patch angioplasty for reconstruction of proximal coronary artery stenosis
Ann. Thorac. Surg., December 1, 1999; 68(6): 2185 - 2189.
[Abstract] [Full Text] [PDF]



Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.