Skip Navigation

Cardiovascular Research 1995 30(6):992-1000; doi:10.1016/S0008-6363(95)00174-3
© 1995 by European Society of Cardiology
This Article
Right arrow Full Text (PDF)
Right arrow E-letters: Submit a response
Right arrow Alert me when this article is cited
Right arrow Alert me when E-letters are posted
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to My Personal Archive
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Disclaimer
Google Scholar
Right arrow Articles by Jackson, M.
Right arrow Articles by Anderson, R.H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jackson, M.
Right arrow Articles by Anderson, R.H.
Social Bookmarking
 Add to CiteULike   Add to Connotea   Add to Del.icio.us  
What's this?

Copyright © 1995, European Society of Cardiology

Common arterial trunk and pulmonary atresia: close developmental cousins? Results from a teratogen induced animal model

M. Jackson*, M.G. Connella, A. Smitha, J. Drurya and R.H. Andersonb

aThe Institute of Child Health, University of Liverpool, Royal Liverpool Children's Hospital Alder Hey, Eaton Road, Liverpool, LI2 2AP, UK
bRoyal Brompton National Heart and Lung Institute, Dovehouse Street, London, SW3 6LY, UK

* Corresponding author. Tel. 051 228 4811, ext. 2438.

Objectives: To examine morphological similarities between "classically different" congenital heart lesion types induced in fetal rats by the cardiac teratogen N,N'-bis(dichloroacetyl)-1,8-octamethylenediamine (bis-diamine). Methods: A single 200 mg oral dose of bis-diamine was given to 50 pregnant rats on the 9th gestational day. Eleven controls were fed an inert vehicle. Experimental and control rats were sacrificed from 15.4 days to term and embryos delivered by caesarean section. Age-matched embryos were processed for histology and sectioned at 7 µm. Cardiac morphology was compared between normal and bis-diamine exposed groups. Results: Hearts from control embryos were morphologically normal. Those from bis-diamine treated embryos exhibited common arterial trunk (32%), overriding aortic valve with valvar pulmonary stenosis (40%) or infundibular atresia (4%), or ventricular septal defect (24%). Development of the outlet septum was affected in all hearts and the arterial duct was absent in 72% of cases. Whilst most hearts demonstrated the anatomy expected for their lesion, some with a common arterial valve demonstrated a pulmonary blood supply similar to that in human cases of pulmonary atresia, where, in the absence of an arterial duct, an essential systemic to pulmonary conduit was provided by a "persistent fifth aortic arch artery". In one such case, the proximal part of the aortopulmonary septum was identified above a common valve. The septum was deviated to the left and was not continuous throughout the length of the arterial trunk, causing atresia of the pulmonary component. Others had muscular infundibular atresia but with a pulmonary blood supply arising directly from the solitary trunk as seen in common arterial trunk "type III". Conclusions: Bis-diamine consistently affects development of those structures which partition the arterial segment of the developing heart at one or more levels, often coexistent with agenesis of the sixth aortic arch arteries. Whilst the aortopulmonary and outlet septums were absent in most cases of common arterial trunk, some morphological duality was shared by classically different lesion types in these rat hearts, which may suggest a common aetiology for common arterial trunk "type III" and aortic overriding with absence of the outlet septum and pulmonary atresia.

KEYWORDS Congenital heart disease; Morphology; Outflow tract; Bis-diamine; Rat; embryonic heart


Add to CiteULike CiteULike   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us    What's this?




Disclaimer: Please note that abstracts for content published before 1996 were created through digital scanning and may therefore not exactly replicate the text of the original print issues. All efforts have been made to ensure accuracy, but the Publisher will not be held responsible for any remaining inaccuracies. If you require any further clarification, please contact our Customer Services Department.